http://wenku.it168.com/d_000767925.shtml

Truecopy 安装实施-包含图

http://www.docin.com/p-261693079.html

来自:http://www.storage.cz/wp-content/uploads/2012/10/HUS-hvezdarna.pdf

HUS110技术指标

http://wenku.baidu.com/view/2b5d8abe1a37f111f1855b3d.html

http://www.hds.com/products/storage-systems/specifications/hus-physical-characteristics.html

Unified Storage Specifications: Physical Characteristics

  HUS VM HUS 150 HUS 150DC HUS 130 HUS 110
Capacity          
Minimum-maximum number of drives (including spares) 0 - 1,152
SFF
0 - 1,152
LFF
4 - 960
SFF
4 - 960
LFF
4 - 960
SFF
4 - 480
LFF
4 - 360
SFF
4 - 360
LFF
4 – 120
SFF 
4 – 120
LFF
Max number of FMDs 96 N/A N/A N/A N/A
Max number of SSDs 128 960 960 360 120
Maximum raw capacity 3,456TB
(3TB, 7200RPM,
SAS)
1,036TB
(900GB, 10K RPM,
SAS)
154TB 
(1.6TB FMD)
51TB 
(400GB 2.5-in. SSD)
64PB - including internal and external virtualized capacity
2,880TB
(3TB, 7200 
RPM, SAS)
864TB 
(900GB, 10K 
RPM, SAS)
384TB 
(400GB, SSD)
1,440TB 
(3TB, 7200 
RPM, SAS)
864TB 
(900GB, 10K 
RPM, SAS)
384TB 
(400GB, SSD)
1,080TB 
(3TB, 7200 
RPM, SAS)
324TB 
(900GB, 10K 
RPM, SAS)
144TB 
(400GB, SSD)
360TB 
(3TB, 7200 
RPM, SAS)
108TB 
(900GB, 10K 
RPM, SAS)
48TB 
(400GB, SSD)
Flash module drive 1.6TB, SAS N/A N/A N/A N/A
Solid state disk options 200GB, MLC, 2.5 in., SAS
400GB, MLC, 2.5 in., SAS
200GB, MLC,
2.5 in., SAS
400GB, MLC,
2.5 in., SAS
200GB, MLC,
2.5 in., SAS
400GB, MLC,
2.5 in., SAS
200GB, MLC, 
2.5 in., SAS
400GB, MLC, 
2.5 in., SAS
200GB, MLC,
2.5 in., SAS
400GB, MLC,
2.5 in., SAS
Hard disk drive options 300GB SAS 
(15K RPM, 2.5 in.)
600GB SAS 
(10K RPM, 2.5 in.)
900GB SAS 
(10K RPM, 2.5 in.)
3TB SAS 
(7200 RPM, 3.5 in.)
300GB SAS 
(15K RPM, 2.5 in.)
300GB SAS 
(10K RPM, 2.5 in.)
600GB SAS 
(10K RPM, 2.5 in.)
900GB SAS 
(10K RPM, 2.5 in.)
2TB SAS (7200 
RPM, 3.5 in.)
3TB SAS (7200 
RPM, 3.5 in.)
300GB SAS 
(15K RPM, 2.5 in.)
300GB SAS 
(10K RPM, 2.5 in.)
600GB SAS 
(10K RPM, 2.5 in.)
900GB SAS 
(10K RPM, 2.5 in.)
2TB SAS (7200 
RPM, 3.5 in.)
3TB SAS (7200 
RPM, 3.5 in.)
300GB SAS 
(15K RPM, 2.5 in.)
300GB SAS 
(10K RPM, 2.5 in.)
600GB SAS 
(10K RPM, 2.5 in.)
900GB SAS 
(10K RPM, 2.5 in.)
2TB SAS (7200 
RPM, 3.5 in.)
3TB SAS (7200 
RPM, 3.5 in.)
300GB SAS 
(15K RPM, 2.5 in.)
300GB SAS 
(10K RPM, 2.5 in.)
600GB SAS 
(10K RPM, 2.5 in.)
900GB SAS 
(10K RPM, 2.5 in.)
2TB SAS (7200 
RPM, 3.5 in.)
3TB SAS (7200 
RPM, 3.5 in.)
Max. Hitachi Accelerated Flash Expansion Trays (2U, 12 x flash module drives) 8 N/A N/A N/A N/A
Maximum standard disk expansion trays (2U, 24 x 2.5 in. disks) 48 40 40 14 4
Maximum standard disk expansion trays (2U, 12 x 3.5 in. disks) 24 40 40 19 9
Maximum dense expansion trays (4U, 48 x 3.5 in.disks) 24 20 0 7 0
Maximum ultra dense expansion trays (5U, 84 x 3.5 in.disks) 0 11 0 4 0
Block Modules          
Number of controller cards 2 (one virtual storage controller) 2 2 2 1 - 2
Architecture Hierarchical 
Star Network
Symmetric 
Active-Active
Symmetric 
Active-Active
Symmetric 
Active-Active
Symmetric 
Active-Active1
Grid Switches Embedded N/A N/A N/A N/A
Height/Width/Depth 5U, 8.5" 
(217mm) x 19.0" 
(480mm) x 33" (838mm)
3U, 5.1 in. 
(129mm)/19.0 in. 
(483mm)/32.2 in. (819mm)
3U, 5.1 in. 
(129mm)/19.0 in. 
(483mm)/32.2 in. (819mm)
2U, 3.3 in. 
(84mm)/19.0 in. 
(483mm)/30.3 in. (770mm)
2U, 3.3 in. 
(84mm)/19.0 in. 
(483mm)/30.3 in. (770mm)
Weight with disks installed 156 lbs. (71kg) 103 lbs. (47kg) 103 lbs. (47kg) 24 SFF disks:
88 lbs. (40kg)

12 LFF disks:
95 lbs. (43kg)
24 SFF disks:
88 lbs. (40kg)

12 LFF disks:
95 lbs. (43kg)
Internal drive slots N/A N/A N/A 12 LFF or
24 SFF
12 LFF or
24 SFF
Mirrored Data Cache 256GB 32GB 32GB 16GB/32GB 8GB 1
Backend SAS links (6Gbps) 32 32 32 16 1
Model upgrade options with data in place N/A N/A N/A HUS 150 N/A
File Modules1, 2          
Recommended File Modules 4080 4080 N/A M2, 4060 M1
Nodes per Cluster 1 - 4 1 - 4 N/A M2: 1 - 4
4060: 1 - 2
1 - 2
Random I/O (estimate) 3 105,000 105,000 N/A M2: 79,058
4060: 70,000
40,688
Height/Width/Depth 3U, 5.1"
(130mm)/
17.2" (437mm)
/27" (685mm)
3U, 5.1" 
(130mm)/
17.2" (437mm)
/27" (685mm)
N/A 3U, 5.1" 
(130mm)/
17.2" (437mm)/
27" (685mm)
3U, 5.1" 
(130mm)/
17.2" (437mm)/
27" (685mm)
Weight 55 lbs. (25kg) 55 lbs. (25kg) N/A 55 lbs. (25kg) 55 lbs. (25kg)
Main Board Memory 46GB (4GB NVRAM) 46GB (4GB NVRAM) N/A M2: 32GB (2GB NVRAM)
4060: 48GB (4GB NVRAM)
32GB (2GB NVRAM)
Number of VLANs 256 256 N/A 256 256
Storage Interconnect Ports 4 x 8Gbps Fibre Channel 4 x 8Gbps Fibre Channel N/A M2: 4 x 4Gbps Fibre Channel
4060: 4 x 8Gbps Fibre Channel
4 x 4Gbps Fibre Channel
Clustering Interconnect Ports 2 x 10Gbps 
Ethernet
2 x 10Gbps 
Ethernet
N/A 2 x 10Gbps 
Ethernet
2 x 10Gbps 
Ethernet

1 Dual block controller card configurations required.
2 File module specs are per node.
3 Based on SPECsfs_2008 NFS benchmarks of equivalent HNAS models.

HDS TrueCopy-数据远程容灾白皮书-IOPS数据的更多相关文章

  1. Hbase数据备份&&容灾方案

    Hbase数据备份&&容灾方案 标签(空格分隔): Hbase 一.Distcp 在使用distcp命令copy hdfs文件的方式实现备份时,需要禁用备份表确保copy时该表没有数据 ...

  2. 入门大数据---Hbase容灾与备份

    一.前言 本文主要介绍 Hbase 常用的三种简单的容灾备份方案,即CopyTable.Export/Import.Snapshot.分别介绍如下: 二.CopyTable 2.1 简介 CopyTa ...

  3. 华为云计算IE面试笔记-请描述华为容灾解决方案全景图,并解释双活数据中心需要从哪些角度着手考虑双活设计

    容灾全景图: 按照距离划分:分为本地容灾 同城容灾 异地容灾  本地容灾包括本地高可用和本地主备.(本数据中心的两机房.机柜) 本地高可用这个方案为了保持业务的连续性,从两个层面来考虑: ①一个是从主 ...

  4. 腾讯云COS对象存储占据数据容灾C位

    说到公有云容灾,大家首先想到的是云上数据备份. 然而,随着企业核心业务逐渐从线下迁移到云上,客户提出了更高的要求.如何确保云上业务的高可用.数据的高可靠,这对云厂商提出了新的挑战. 腾讯云作为全球领先 ...

  5. diamond专题(四)—— 容灾机制

    大家好,本次为大家带来diamond的容灾机制. diamond之所以表现的稳定可靠,除了架构简单之外,另一个重要原因是diamond具有一套完备的容灾机制,容灾机制涉及到client和server两 ...

  6. 双机热备(准)-->RAC(夭折)-->DG(异地容灾)

    以下有的地方为oracle专业术语,非懂勿喷.前段时间某项目负责人告知,他们应用需要一套oracle数据库环境运行模式为双机热备.简单了解下对于现在已经非常成熟的RAC再合适不过了.详细问了问当前服务 ...

  7. Redis全方位详解--磁盘持久化和容灾备份

    序言 在上一篇博客中,博客介绍了redis的数据类型使用场景和redis分布式锁的正确姿势.我们知道一旦Redis重启,存在redis里面的数据就会全部丢失.所以这篇博客中向大家介绍Redis的磁盘持 ...

  8. 容灾管理中的RTO与RPO的关系

    在灾难恢复方面,目前业界公认有三个目标值得努力.一是恢复时间,企业能忍受多长时间没有 IT,处于停业状态:二是网络多长时间能够恢复:三是业务层面的恢复.整个恢复过程中,最关键的衡量指标有两个:一个是 ...

  9. 【转】diamond专题(四)—— 容灾机制

    特别提示:本人博客部分有参考网络其他博客,但均是本人亲手编写过并验证通过.如发现博客有错误,请及时提出以免误导其他人,谢谢!欢迎转载,但记得标明文章出处:http://www.cnblogs.com/ ...

随机推荐

  1. Linux学习15-CentOS安装mysql5.6环境

    前言 在linux上安装mysql5.6版本,并远程连接mysql数据库操作 安装mysql mysql的安装可以用yum安装更方便 [root@yoyo ~]# cd /usr/local/ [ro ...

  2. 实用ExtJS教程100例-010:ExtJS Form异步加载和提交数据

    ExtJS Form 为我们提供了两个方法:load 和 submit,分别用来加载和提交数据,这两个方法都是异步的. 系列ExtJS教程持续更新中,点击查看>>最新ExtJS教程目录 F ...

  3. 自定义各式各样的圆形ProgressBar

         上面三个图分别是 开始时的样子,走进度时候的样子,最后完成的样子 这是我在两个大神的Demo基础上修改后的结果,我们先来看看自定义view是怎么做到的. 1.自己写一个类继承View类,然后 ...

  4. Svg.js 图片加载

    一.SVG.Image 1.创建和修改图片 var draw = SVG('svg1').size(300, 300); //SVG.Image 加载图片文件 var image = draw.ima ...

  5. Java(C#)基础差异-语法

    1.long类型 Java long类型,若赋值大于int型的最大值,或小于int型的最小值,则需要在数字后加L或者l,表示该数值为长整数,如long num=2147483650L. 举例如下: p ...

  6. MVC详解(转)

    原文链接:MVC详解 MVC与模板概念的理解 MVC(Model View Controller)模型-视图-控制器   MVC本来是存在于Deskt op程序中的,M是指数据模型,V是指用户界面,C ...

  7. 算法: skiplist 跳跃表代码实现和原理

    SkipList在leveldb以及lucence中都广为使用,是比较高效的数据结构.由于它的代码以及原理实现的简单性,更为人们所接受. 所有操作均从上向下逐层查找,越上层一次next操作跨度越大.其 ...

  8. 不用中间变量交换两个数 swap(a,b);

    #include <iostream> using namespace std; int main () { ; ; cout<<"a="<<a ...

  9. 阅读日志: 微信小程序的风口只有一天?

    原文地址: 小程序的风口只有一天?难道我们用的是假的小程序 http://xudanei.baijia.baidu.com/article/755506 原文摘要: #,小程序的趋势,从1月10日至1 ...

  10. ORM数据库框架 SQLite ORMLite MD

    Markdown版本笔记 我的GitHub首页 我的博客 我的微信 我的邮箱 MyAndroidBlogs baiqiantao baiqiantao bqt20094 baiqiantao@sina ...