Prometheus中使用的告警规则
参考网站:https://awesome-prometheus-alerts.grep.to/rules
这个网站上有好多常用软件的告警规则,但是有些并不一定实用,有些使用起来会有错误,这里就把这些都给排除掉,只保留能使用的
结合文章:https://www.cnblogs.com/sanduzxcvbnm/p/13589792.html 来使用
1.prometheus自身的告警规则
groups:
- name: prometheus_rules
rules:
- alert: PrometheusJobMissing
expr: absent(up{job="prometheus"})
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus job missing (instance {{ $labels.instance }})
description: "A Prometheus job has disappeared\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTargetMissing
expr: up == 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus target missing (instance {{ $labels.instance }})
description: "A Prometheus target has disappeared. An exporter might be crashed.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusAllTargetsMissing
expr: count by (job) (up) == 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus all targets missing (instance {{ $labels.instance }})
description: "A Prometheus job does not have living target anymore.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusConfigurationReloadFailure
expr: prometheus_config_last_reload_successful != 1
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus configuration reload failure (instance {{ $labels.instance }})
description: "Prometheus configuration reload error\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTooManyRestarts
expr: changes(process_start_time_seconds{job=~"prometheus|pushgateway|alertmanager"}[15m]) > 2
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus too many restarts (instance {{ $labels.instance }})
description: "Prometheus has restarted more than twice in the last 15 minutes. It might be crashlooping.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusAlertmanagerConfigurationReloadFailure
expr: alertmanager_config_last_reload_successful != 1
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus AlertManager configuration reload failure (instance {{ $labels.instance }})
description: "AlertManager configuration reload error\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusAlertmanagerConfigNotSynced
expr: count(count_values("config_hash", alertmanager_config_hash)) > 1
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus AlertManager config not synced (instance {{ $labels.instance }})
description: "Configurations of AlertManager cluster instances are out of sync\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusNotConnectedToAlertmanager
expr: prometheus_notifications_alertmanagers_discovered < 1
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus not connected to alertmanager (instance {{ $labels.instance }})
description: "Prometheus cannot connect the alertmanager\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusRuleEvaluationFailures
expr: increase(prometheus_rule_evaluation_failures_total[3m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus rule evaluation failures (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} rule evaluation failures, leading to potentially ignored alerts.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTemplateTextExpansionFailures
expr: increase(prometheus_template_text_expansion_failures_total[3m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus template text expansion failures (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} template text expansion failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusRuleEvaluationSlow
expr: prometheus_rule_group_last_duration_seconds > prometheus_rule_group_interval_seconds
for: 5m
labels:
severity: warning
annotations:
summary: Prometheus rule evaluation slow (instance {{ $labels.instance }})
description: "Prometheus rule evaluation took more time than the scheduled interval. It indicates a slower storage backend access or too complex query.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusNotificationsBacklog
expr: min_over_time(prometheus_notifications_queue_length[10m]) > 0
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus notifications backlog (instance {{ $labels.instance }})
description: "The Prometheus notification queue has not been empty for 10 minutes\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusAlertmanagerNotificationFailing
expr: rate(alertmanager_notifications_failed_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus AlertManager notification failing (instance {{ $labels.instance }})
description: "Alertmanager is failing sending notifications\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTargetEmpty
expr: prometheus_sd_discovered_targets == 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus target empty (instance {{ $labels.instance }})
description: "Prometheus has no target in service discovery\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTargetScrapingSlow
expr: prometheus_target_interval_length_seconds{quantile="0.9"} > 60
for: 5m
labels:
severity: warning
annotations:
summary: Prometheus target scraping slow (instance {{ $labels.instance }})
description: "Prometheus is scraping exporters slowly\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusLargeScrape
expr: increase(prometheus_target_scrapes_exceeded_sample_limit_total[10m]) > 10
for: 5m
labels:
severity: warning
annotations:
summary: Prometheus large scrape (instance {{ $labels.instance }})
description: "Prometheus has many scrapes that exceed the sample limit\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTargetScrapeDuplicate
expr: increase(prometheus_target_scrapes_sample_duplicate_timestamp_total[5m]) > 0
for: 0m
labels:
severity: warning
annotations:
summary: Prometheus target scrape duplicate (instance {{ $labels.instance }})
description: "Prometheus has many samples rejected due to duplicate timestamps but different values\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbCheckpointCreationFailures
expr: increase(prometheus_tsdb_checkpoint_creations_failed_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB checkpoint creation failures (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} checkpoint creation failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbCheckpointDeletionFailures
expr: increase(prometheus_tsdb_checkpoint_deletions_failed_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB checkpoint deletion failures (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} checkpoint deletion failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbCompactionsFailed
expr: increase(prometheus_tsdb_compactions_failed_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB compactions failed (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} TSDB compactions failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbHeadTruncationsFailed
expr: increase(prometheus_tsdb_head_truncations_failed_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB head truncations failed (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} TSDB head truncation failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbReloadFailures
expr: increase(prometheus_tsdb_reloads_failures_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB reload failures (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} TSDB reload failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbWalCorruptions
expr: increase(prometheus_tsdb_wal_corruptions_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB WAL corruptions (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} TSDB WAL corruptions\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: PrometheusTsdbWalTruncationsFailed
expr: increase(prometheus_tsdb_wal_truncations_failed_total[1m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: Prometheus TSDB WAL truncations failed (instance {{ $labels.instance }})
description: "Prometheus encountered {{ $value }} TSDB WAL truncation failures\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
2.node主机的告警规则
groups:
- name: node_rules
rules:
- alert: HostOutOfMemory
expr: node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10
for: 2m
labels:
severity: warning
annotations:
summary: Host out of memory (instance {{ $labels.instance }})
description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostMemoryUnderMemoryPressure
expr: rate(node_vmstat_pgmajfault[1m]) > 1000
for: 2m
labels:
severity: warning
annotations:
summary: Host memory under memory pressure (instance {{ $labels.instance }})
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualNetworkThroughputIn
expr: sum by (instance) (rate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual network throughput in (instance {{ $labels.instance }})
description: "Host network interfaces are probably receiving too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualNetworkThroughputOut
expr: sum by (instance) (rate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual network throughput out (instance {{ $labels.instance }})
description: "Host network interfaces are probably sending too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskReadRate
expr: sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual disk read rate (instance {{ $labels.instance }})
description: "Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskWriteRate
expr: sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write rate (instance {{ $labels.instance }})
description: "Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# Please add ignored mountpoints in node_exporter parameters like
# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)".
# Same rule using "node_filesystem_free_bytes" will fire when disk fills for non-root users.
- alert: HostOutOfDiskSpace
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host out of disk space (instance {{ $labels.instance }})
description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# Please add ignored mountpoints in node_exporter parameters like
# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)".
# Same rule using "node_filesystem_free_bytes" will fire when disk fills for non-root users.
- alert: HostDiskWillFillIn24Hours
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host disk will fill in 24 hours (instance {{ $labels.instance }})
description: "Filesystem is predicted to run out of space within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOutOfInodes
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint="/rootfs"} * 100 < 10 and ON (instance, device, mountpoint) node_filesystem_readonly{mountpoint="/rootfs"} == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host out of inodes (instance {{ $labels.instance }})
description: "Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostInodesWillFillIn24Hours
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint="/rootfs"} * 100 < 10 and predict_linear(node_filesystem_files_free{mountpoint="/rootfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly{mountpoint="/rootfs"} == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host inodes will fill in 24 hours (instance {{ $labels.instance }})
description: "Filesystem is predicted to run out of inodes within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskReadLatency
expr: rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk read latency (instance {{ $labels.instance }})
description: "Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskWriteLatency
expr: rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 0.1 and rate(node_disk_writes_completed_total[1m]) > 0
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write latency (instance {{ $labels.instance }})
description: "Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostHighCpuLoad
expr: 100 - (avg by(instance) (rate(node_cpu_seconds_total{mode="idle"}[2m])) * 100) > 80
for: 0m
labels:
severity: warning
annotations:
summary: Host high CPU load (instance {{ $labels.instance }})
description: "CPU load is > 80%\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostCpuStealNoisyNeighbor
expr: avg by(instance) (rate(node_cpu_seconds_total{mode="steal"}[5m])) * 100 > 10
for: 0m
labels:
severity: warning
annotations:
summary: Host CPU steal noisy neighbor (instance {{ $labels.instance }})
description: "CPU steal is > 10%. A noisy neighbor is killing VM performances or a spot instance may be out of credit.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# 1000 context switches is an arbitrary number.
# Alert threshold depends on nature of application.
# Please read: https://github.com/samber/awesome-prometheus-alerts/issues/58
- alert: HostContextSwitching
expr: (rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 1000
for: 0m
labels:
severity: warning
annotations:
summary: Host context switching (instance {{ $labels.instance }})
description: "Context switching is growing on node (> 1000 / s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostSwapIsFillingUp
expr: (1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80
for: 2m
labels:
severity: warning
annotations:
summary: Host swap is filling up (instance {{ $labels.instance }})
description: "Swap is filling up (>80%)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostSystemdServiceCrashed
expr: node_systemd_unit_state{state="failed"} == 1
for: 0m
labels:
severity: warning
annotations:
summary: Host systemd service crashed (instance {{ $labels.instance }})
description: "systemd service crashed\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostPhysicalComponentTooHot
expr: node_hwmon_temp_celsius > 75
for: 5m
labels:
severity: warning
annotations:
summary: Host physical component too hot (instance {{ $labels.instance }})
description: "Physical hardware component too hot\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNodeOvertemperatureAlarm
expr: node_hwmon_temp_crit_alarm_celsius == 1
for: 0m
labels:
severity: critical
annotations:
summary: Host node overtemperature alarm (instance {{ $labels.instance }})
description: "Physical node temperature alarm triggered\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRaidArrayGotInactive
expr: node_md_state{state="inactive"} > 0
for: 0m
labels:
severity: critical
annotations:
summary: Host RAID array got inactive (instance {{ $labels.instance }})
description: "RAID array {{ $labels.device }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRaidDiskFailure
expr: node_md_disks{state="failed"} > 0
for: 2m
labels:
severity: warning
annotations:
summary: Host RAID disk failure (instance {{ $labels.instance }})
description: "At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostKernelVersionDeviations
expr: count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1
for: 6h
labels:
severity: warning
annotations:
summary: Host kernel version deviations (instance {{ $labels.instance }})
description: "Different kernel versions are running\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOomKillDetected
expr: increase(node_vmstat_oom_kill[1m]) > 0
for: 0m
labels:
severity: warning
annotations:
summary: Host OOM kill detected (instance {{ $labels.instance }})
description: "OOM kill detected\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacCorrectableErrorsDetected
expr: increase(node_edac_correctable_errors_total[1m]) > 0
for: 0m
labels:
severity: info
annotations:
summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacUncorrectableErrorsDetected
expr: node_edac_uncorrectable_errors_total > 0
for: 0m
labels:
severity: warning
annotations:
summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkReceiveErrors
expr: rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Receive Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} receive errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkTransmitErrors
expr: rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Transmit Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} transmit errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkInterfaceSaturated
expr: (rate(node_network_receive_bytes_total{device!~"^tap.*"}[1m]) + rate(node_network_transmit_bytes_total{device!~"^tap.*"}[1m])) / node_network_speed_bytes{device!~"^tap.*"} > 0.8
for: 1m
labels:
severity: warning
annotations:
summary: Host Network Interface Saturated (instance {{ $labels.instance }})
description: "The network interface \"{{ $labels.interface }}\" on \"{{ $labels.instance }}\" is getting overloaded.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostConntrackLimit
expr: node_nf_conntrack_entries / node_nf_conntrack_entries_limit > 0.8
for: 5m
labels:
severity: warning
annotations:
summary: Host conntrack limit (instance {{ $labels.instance }})
description: "The number of conntrack is approching limit\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostClockSkew
expr: (node_timex_offset_seconds > 0.05 and deriv(node_timex_offset_seconds[5m]) >= 0) or (node_timex_offset_seconds < -0.05 and deriv(node_timex_offset_seconds[5m]) <= 0)
for: 2m
labels:
severity: warning
annotations:
summary: Host clock skew (instance {{ $labels.instance }})
description: "Clock skew detected. Clock is out of sync.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostClockNotSynchronising
expr: min_over_time(node_timex_sync_status[1m]) == 0 and node_timex_maxerror_seconds >= 16
for: 2m
labels:
severity: warning
annotations:
summary: Host clock not synchronising (instance {{ $labels.instance }})
description: "Clock not synchronising.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
3.mysql告警规则
groups:
- name: mysql_rules
rules:
- alert: MysqlDown
expr: mysql_up == 0
for: 0m
labels:
severity: critical
annotations:
summary: MySQL down (instance {{ $labels.instance }})
description: "MySQL instance is down on {{ $labels.instance }}\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlTooManyConnections(>80%)
expr: avg by (instance) (rate(mysql_global_status_threads_connected[1m])) / avg by (instance) (mysql_global_variables_max_connections) * 100 > 80
for: 2m
labels:
severity: warning
annotations:
summary: MySQL too many connections (> 80%) (instance {{ $labels.instance }})
description: "More than 80% of MySQL connections are in use on {{ $labels.instance }}\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlHighThreadsRunning
expr: avg by (instance) (rate(mysql_global_status_threads_running[1m])) / avg by (instance) (mysql_global_variables_max_connections) * 100 > 60
for: 2m
labels:
severity: warning
annotations:
summary: MySQL high threads running (instance {{ $labels.instance }})
description: "More than 60% of MySQL connections are in running state on {{ $labels.instance }}\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlSlaveIoThreadNotRunning
expr: mysql_slave_status_master_server_id > 0 and ON (instance) mysql_slave_status_slave_io_running == 0
for: 0m
labels:
severity: critical
annotations:
summary: MySQL Slave IO thread not running (instance {{ $labels.instance }})
description: "MySQL Slave IO thread not running on {{ $labels.instance }}\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlSlaveSqlThreadNotRunning
expr: mysql_slave_status_master_server_id > 0 and ON (instance) mysql_slave_status_slave_sql_running == 0
for: 0m
labels:
severity: critical
annotations:
summary: MySQL Slave SQL thread not running (instance {{ $labels.instance }})
description: "MySQL Slave SQL thread not running on {{ $labels.instance }}\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlSlaveReplicationLag
expr: mysql_slave_status_master_server_id > 0 and ON (instance) (mysql_slave_status_seconds_behind_master - mysql_slave_status_sql_delay) > 30
for: 1m
labels:
severity: critical
annotations:
summary: MySQL Slave replication lag (instance {{ $labels.instance }})
description: "MySQL replication lag on {{ $labels.instance }}\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlSlowQueries
expr: increase(mysql_global_status_slow_queries[1m]) > 0
for: 2m
labels:
severity: warning
annotations:
summary: MySQL slow queries (instance {{ $labels.instance }})
description: "MySQL server mysql has some new slow query.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlInnodbLogWaits
expr: rate(mysql_global_status_innodb_log_waits[15m]) > 10
for: 0m
labels:
severity: warning
annotations:
summary: MySQL InnoDB log waits (instance {{ $labels.instance }})
description: "MySQL innodb log writes stalling\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: MysqlRestarted
expr: mysql_global_status_uptime < 60
for: 0m
labels:
severity: info
annotations:
summary: MySQL restarted (instance {{ $labels.instance }})
description: "MySQL has just been restarted, less than one minute ago on {{ $labels.instance }}.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
Prometheus中使用的告警规则的更多相关文章
- Prometheus自身的监控告警规则
1.先在 Prometheus 主程序目录下创建rules目录,然后在该目录下创建 prometheus-test.yml文件,内容如下: 内容很多,可以根据实际情况进行调整. 规则参考网址:http ...
- k8s实战之部署Prometheus+Grafana可视化监控告警平台
写在前面 之前部署web网站的时候,架构图中有一环节是监控部分,并且搭建一套有效的监控平台对于运维来说非常之重要,只有这样才能更有效率的保证我们的服务器和服务的稳定运行,常见的开源监控软件有好几种,如 ...
- Prometheus监控学习笔记之Prometheus 2.0 告警规则介绍
0x00 变化 Prometheus 2.0 已经发布一段时间了,从今天开始我将分几篇文章为大家介绍其中的一些变化. 此篇文章主要介绍 2.0 的告警规则声明的新写法. 从 1.x 到 2.0 规则声 ...
- Prometheus告警规则增删改自动化
Prometheus告警规则增删改自动化 前言: 随着容器技术的发展,zabbix监控方式与k8s的结合不完善,导致不得不放弃zabbix,而新的监控工具prometheus的使用就越来越多了.但是经 ...
- 实用干货丨如何使用Prometheus配置自定义告警规则
前 言 Prometheus是一个用于监控和告警的开源系统.一开始由Soundcloud开发,后来在2016年,它迁移到CNCF并且称为Kubernetes之后最流行的项目之一.从整个Linux服务器 ...
- Prometheus之告警规则的编写
Prometheus之告警规则的编写 一.前置知识 二.需求 三.实现步骤 1.编写告警规则 2.修改prometheus.yml执行告警规则的位置 3.配置文件截图 4.页面上看告警数据信息 5.查 ...
- Prometheus 编写告警规则案例
Prometheus 编写告警规则案例 注:确保alertmanager配置完毕! 1.创建编辑文件:vim /usr/local/prometheus/rules/node.yml # groups ...
- prometheus linux系统告警规则 实例
#prometheus linux系统告警规则 实例 #根据实际情况修改参数 #rules.linux.yml groups: - name: linux rules: - alert: Node-D ...
- 记录规则(recording rules)与告警规则(alerting rule)
记录规则(recording rules) 配置规则 Prometheus支持两种类型的规则,可以对其进行配置,然后定期进行评估:记录规则和警报规则.要在Prometheus中包含规则,请创建一个包含 ...
随机推荐
- 小白对Java的呐喊
1 public class Hello{ 2 public static void main(string[] args){ 3 System.out.print("hello world ...
- C# 实例解释面向对象编程中的接口隔离原则
在面向对象编程中,SOLID 是五个设计原则的首字母缩写,旨在使软件设计更易于理解.灵活和可维护.这些原则是由美国软件工程师和讲师罗伯特·C·马丁(Robert Cecil Martin)提出的许多原 ...
- 2022 07 13 第一小组 田龙跃 Java再学习笔记
1.类名命名规则: 只能由数字字母,下划线,美元符号组成(不能以数字开头,尽量不要用下划线开头) 2.注释(养成多写注释的好习惯) 单行注释 // ctrl+/ 多行注释 // ctrl+shirt+ ...
- nginx虚拟主机测试
一.基于域名的nginx虚拟主机 基于域名的nginx虚拟主机的操作步骤: 1 .为虚拟主机提供域名和IP的映射(也可以使用DNS正向解析) echo "172.16.10.101 www. ...
- 函数式接口的概念&函数式接口的定义和函数式接口的使用
函数式接口概念 函数式接口在Java中是指:有且仅有一个抽象方法的接口. 函数式接口,即适用于函数式编程场景的接口.而Java中的函数式编程体现就是Lambda,所以函数式接口就是可以适用于Lambd ...
- 企业运维实践-还不会部署高可用的kubernetes集群?使用kubeadm方式安装高可用k8s集群v1.23.7
关注「WeiyiGeek」公众号 设为「特别关注」每天带你玩转网络安全运维.应用开发.物联网IOT学习! 希望各位看友[关注.点赞.评论.收藏.投币],助力每一个梦想. 文章目录: 0x00 前言简述 ...
- word-break,word-wrap,line-break相关知识
1.word-break: break-word与word-wrap: break-word的区别? 答:计算最小宽度(width: min-content)时有区别,word-break: brea ...
- 什么是 Base64 ?
Base64 是什么? Base64是一种二进制到文本的编码方式.如果要更具体一点的话,可以认为它是一种将 byte数组编码为字符串的方法,而且编码出的字符串只包含ASCII基础字符,就是包括小写字母 ...
- python 可变、不可变类型、深拷贝、浅拷贝理解
简介 python中数据分为可变类型,不可变类型.不同的数据类型影响着不同情况下的深浅拷贝. 下面则将简要介绍一下 可变类型 当某个数据的值发生改变时,它对应的内存地址不发生改变,常见的有列表.字典. ...
- 丽泽普及2022交流赛day15 社论
前言 link 太牛逼了,补完我一定放代码 . orz 越看越牛逼 orz . 时间复杂度都是口胡,不要信 . 以下是目录 目录 目录 前言 A 题面 题解 代码 B 题面 题解 代码 C 题面 题解 ...