[转]Rapidly detecting large flows, sFlow vs. NetFlow/IPFIX

Figure 1: Low latency software defined networking control loop
The articles SDN and delay and Delay and stability describe the critical importance of low measurement delay in constructing stable and effective controls. This article will examine the difference in measurement latency between sFlow and NetFlow/IPFIX and their relative suitability for driving control decisions.

Figure 2: sFlow and NetFlow agent architectures
Figure 2 illustrates shows the architectural differences between the sFlow and IPFIX/NetFlow instrumentation in a switch:
- NetFlow/IPFIX Cisco NetFlow and IPFIX (the IETF standard based on NetFlow) define a protocol for exporting flow records. A flow record summarizes a set of packets that share common attributes - for example, a typical flow record includes ingress interface, source IP address, destination IP address, IP protocol, source TCP/UDP port, destination TCP/UDP port, IP ToS, start time, end time, packet count and byte count. Figure 2 shows the steps performed by the switch in order to construct flow records. First the stream of packets is likely to be sampled (particularly in high-speed switches). Next, the sampled packet header is decoded to extract key fields. A hash function is computed over the keys in order to look up the flow record in the flow cache. If an existing record is found, its values are updated, otherwise a record is created for the new flow. Records are flushed from the cache based on protocol information (e.g. if a FIN flag is seen in a TCP packet), a timeout, inactivity, or when the cache is full. The flushed records are finally sent to the traffic analysis application.
- sFlow With sFlow monitoring, the decode, hash, flow cache and flush functionality are no longer implemented on the switch. Instead, sampled packet headers are immediately sent to the traffic analysis application which decodes the packets and analyzes the data. In addition, sFlow provides a polling function, periodically sending standard interface counters to the traffic analysis applications, eliminating the need for SNMP polling, see Link utilization.
The flow cache introduces significant measurement delay for NetFlow/IPFIX based monitoring since the measurements are only accessible to management applications once they are flushed from the cache and sent to a traffic analyzer. In contrast, sFlow has no cache - measurement are immediately sent and can be quickly acted upon, resulting in extremely low measurement delay.
Open vSwitch is a useful testbed for demonstrating the impact of the flow cache on measurement delay since it can simultaneously export both NetFlow and sFlow, allowing a side-by-side comparison. The article, Comparing sFlow and NetFlow in a vSwitch, describes how to configure sFlow and NetFlow on the Open vSwitch and demonstrates some of the differences between the two measurement technologies. However, this article focusses on the specific issue of measurement delay.
Figure 3 shows the experimental setup, with sFlow directed to InMon sFlow-RT and NetFlow directed to SolarWinds Real-Time NetFlow Analyzer.
Note: Both tools are available at no charge, making it easy for anyone to reproduce these results.

Figure 3: Latency of large flow detection using sFlow and NetFlow
The charts in Figure 3 show how each technology reports on a large data transfer. The charts have been aligned to have the same time axis so you can easily compare them. The vertical blue line indicates the start of the data transfer.
- sFlow By analyzing the continuous stream of sFlow messages from the switch, sFlow-RT immediately detects and continuously tracks the data transfer from the moment the data transfer starts to its completions just over two minutes later.
- NetFlow The Real-Time NetFlow Analyzer doesn't report on the transfer until it receives the first NetFlow record 60 seconds after the data transfer started, indicated by the first vertical red line. The 60 delay corresponds to the active timeout used to flush records from the flow cache. A second NetFlow record, indicated by the second red line, is responsible for the second spike 60 seconds later, and a final NetFlow record, received after the transfer completes and indicated by the third red line, is responsible for the third spike in the chart.
Note: A one minute active timeout is the lowest configurable value on many Cisco switches (the default is 30 minutes), see Configuring NetFlow and NetFlow Data Export.
The large measurement delay imposed by the NetFlow/IPFIX flow cache makes the technology unsuitable for SDN control applications. The measurement delay can lead to instability since the controller is never sure of the current traffic levels and may be taking action based on stale data reported for flows that are no longer active.
In contrast, the sFlow measurement system quickly detects and continuously tracks large flows, allowing an SDN traffic management application to reconfigure switches and balance the paths that active flows take across the network.
[转]Rapidly detecting large flows, sFlow vs. NetFlow/IPFIX的更多相关文章
- [转]Comparing sFlow and NetFlow in a vSwitch
As virtualization shifts the network edge from top of rack switches to software virtual switches run ...
- 别以为真懂Openstack: 虚拟机创建的50个步骤和100个知识点(4)
六.Libvirt 对于Libvirt,在启动虚拟机之前,首先需要define虚拟机,是一个XML格式的文件 列出所有的Instance # virsh list Id Name ...
- BlackArch-Tools
BlackArch-Tools 简介 安装在ArchLinux之上添加存储库从blackarch存储库安装工具替代安装方法BlackArch Linux Complete Tools List 简介 ...
- Go 语言相关的优秀框架,库及软件列表
If you see a package or project here that is no longer maintained or is not a good fit, please submi ...
- 高效的DDoS攻击探测与分析工具——FastNetMon
一.简介 FastNetMon这是一个基于多种抓包引擎(NetFlow, IPFIX, sFLOW, netmap, PF_RING, PCAP)的DoS/DDoS攻击高效分析工具,可以探测和分析网络 ...
- The Best Hacking Tools
The Best Hacking Tools Hacking Tools : List of security tools specifically aimed toward security pro ...
- openvswith Frequently Asked Questions
Open vSwitch <http://openvswitch.org> 参考地址:http://git.openvswitch.org/cgi-bin/gitweb.cgi?p=ope ...
- DataOps Reading Notes
质量.效率.成本.安全,是运维工作核心四要素. AIOps 技术会涉及到数据收集方面的基础监控,服务监控和业务监控,甚至会涉及到与持续交付流水线的数据和状态整合(比如在软件发布的阶段会自动关闭某些监控 ...
- SDN实验---OVS了解(转载)
转载自:https://opengers.github.io/openstack/openstack-base-use-openvswitch/ 一:Open vSwitch介绍 (一)介绍 在过去, ...
随机推荐
- pip升级后出现cannot import name 'main'
运行pip install --upgrade pip还有出现这个情况. cd /usr/bin/pip3 修改成: from pip import __main__ if __name__ == ...
- 记录Queue插入的时候报错
Queue 队列 特性 先进先出 和栈 Stack 非常相似 不过 栈 遵循 后进先出 Queue 和Stack 都存在数据并发的 问题 public static Queue<P ...
- java关于get/post请求
package com.study.test; import java.io.BufferedReader;import java.io.IOException;import java.io.Inpu ...
- c# post方法亲测可用
/// <summary> /// Post接口方法 /// </summary> /// <param name="requestUri">& ...
- DOCKER学习 docker
DOCKER只能安装到LIUX系列机器上 如果WINDOWS想安装必须通过虚拟机来完成. 比如用VM,VBOX等 安装之前需要用ROOT账户 su 安装DOCKER (CE是个人版本,EE是企业版本) ...
- 网址导航19A
[导航] KIM主页 265导航 好866 [名站] 百度 网易 腾讯 新华 中新 凤凰 [新闻] 联合早报 南方周末 澎湃新闻 [系统] 宋永志 蒲公英 技术员 装机网 系统之家 [软件] 星愿 ...
- HTML-CSS背景渐进色
一.分类 a>线性渐变:颜色沿着一条直线过度:从 左到右.从上到下等: b>径向渐变:圆形或椭圆形渐变,颜色不再沿着一条直线变化,而是从一个起点朝所有方向混合. 1.线性渐变语法: bac ...
- zookeeper资料
ZooKeeper 入门
- [二分答案][NOIP2015]跳石头
跳石头 题目描述 一年一度的“跳石头”比赛又要开始了!这项比赛将在一条笔直的河道中进行,河道中分布着一些巨大岩石.组委会已经选择好了两块岩石作为比赛起点和终点.在起点和终点之间,有 N 块岩石(不含起 ...
- 旅游类App的原型制作分享-Klook
Klook是一款旅游类App,它能探索和预订惊人的旅行活动.在世界各地以最优惠的价格畅玩. 这款原型中,用到了Mockplus的两种滚动方式,一种是把手机外壳拉长,另一种是使用滚动区组件,其中,滚动区 ...