参考文档  idrac7-8-lifecycle-controller-v2.40.40.40_Reference Guide_en-us

0、下文中账户名密码均省略-r <RAC IP address> -u root -p <password>

1、使用racadm远程命令

Remote RACADM usage syntax:

racadm -r <RAC IP address> -u <username> -p <password> <subcommand> <options>

racadm -r <RAC IP address> -i <subcommand> <options>

Security Alert: Certificate is invalid - self signed certificate

Continuing execution. Use -S option for racadm to stop execution on certificate-related errors.

使用 --nocertwarn 可以忽略警告

2、racadm help

#racadm --nocertwarn  help

3、racadm help get   获取idrac信息(也可以形成文件)

racadm get <fqdd alias>.<group>

racadm get <fqdd alias>.<group>.<object>

racadm get <fqdd alias>.<group>.<index>.<object>

racadm get -f <filename>

racadm get -f <filename> -t <filetype> -u <username> -p <password>

-l <CIFS share> -c <FQDD>

racadm get -f <filename> -t <filetype> -l <NFS share> -c <FQDD>

4、racadm get iDRAC.NIC.DNSRacName 获取idrac Name

5、racadm set iDRAC.SNMP.Alert.1.DestAddr <IP address> 设置snmp的报警地址

racadm set iDRAC.IPMILan.AlertEnable enabled设置警报为已启用

racadm eventfilters set -c idrac.alert.all -a none -n email,snmp  设置警报类型

6、racadm set iDRAC.Time.Timezone Asia/Shanghai iDRAC设置timezone

7、racadm storage get pdisks  获取磁盘信息

更多的命令可以通过帮助找到

Racadm设置idrac的更多相关文章

  1. dell服务器快速设置idrac

    前提:将服务器专用的idrac网络接口,连接到网络上 1.登录到服务器(即被监控的服务器). 2.安装客户端工具 yum  install  OpenIPMI OpenIPMI-devel OpenI ...

  2. DELL服务器iDRAC相关设置

    iDRAC又称为Integrated Dell Remote Access Controller,也就是集成戴尔远程控制卡 iDRAC卡相当于是附加在服务器上的一台小电脑,通过与服务器主板上的管理芯片 ...

  3. 戴尔iDRAC服务器远程控制设置

    对于远程的服务器,我们不能经常性的去机房维护,所以远程控制对于服务器来说就显得至关重要.那么你是用什么方式对服务器进行远程控制呢?远程桌面?还是KVM切换器?NO,你OUT了!如果你用的是戴尔的服务器 ...

  4. DELL服务器管理工具和RACADM介绍

    DELL服务器管理工具和RACADM介绍 一.Dell服务器管理工具介绍 Dell对服务器(DELL PowerEdge)的管理主要提供了三种管理工具,分别是Dell Remote Access Co ...

  5. 远程控制卡 使用ipmitools设置ipmi

    远程控制卡 使用ipmitools设置ipmi 使用DELL的远程控制卡可以方便的管理服务器 在CentOS中可以使用ipmitools管理 IPMI( Intelligent Platform Ma ...

  6. ipmi监控主机

    author: headsen   chen date: 2018-09-25  20:04:01 IPMI介绍       IPMI(Intelligent Platform Management ...

  7. zabbix snmp 协议监控 dell iRDAC

    转摘:http://blog.csdn.net/wanglei_storage/article/details/52789921 http://blog.csdn.net/wanglei_storag ...

  8. PC Server远程管理卡用户管理脚本实现

    1.IPMI工作原理图: 2.脚本实现流程图: 3.适配服务器机型: 4.演示效果: 5.实现代码: #!/usr/bin/env bash # Author : JACK ZHAO # Date : ...

  9. dell iDRAC7配置远程访问管理

    一.启动Dell服务器,按F2 System Setup,打开BIOS界面,选择iDRAC Settings 二.在IDRAC Settings界面中选择Network 三.在Network界面中 E ...

随机推荐

  1. centos 6.5 gdb 7.10安装make[5]: *** [install-bfdincludeHEADERS] Error 1解决

    make[5]: *** [install-bfdincludeHEADERS] Error 1make[5]: Leaving directory `/usr/local/gdb-7.10/bfd' ...

  2. 写给大忙人的Elasticsearch架构与概念(未完待续)

    最新版本官方文档https://www.elastic.co/guide/en/elasticsearch/reference/current/index.html文档增删改参考https://www ...

  3. 20145221高其_Web安全基础实践

    20145221高其_Web安全基础实践 目录 实践目标 WebGoat BurpSuite Injection Flaws Cross-Site Scripting (XSS) 总结 实践目标 (1 ...

  4. struts2 action中字符串转json对象出错 java.lang.NoClassDefFoundError: org/apache/commons/lang/exception/NestableRuntimeException

    commons-lang包有错,要么是引入错误,要么是没引入. 报不同错误,引入不同包. commons-beanutils-1.8.0.jar不加这个包 java.lang.NoClassDefFo ...

  5. python --- 20 约束 异常处理 MD5 日志

    一.类的约束 1.抛出异常    NotImplementedError 2.抽象方法 含有抽象方法的类是抽象类 抽象类中的方法全是抽象方法的是接口 抽象类不能创建对象 二.异常处理 处理完后代码可继 ...

  6. topcoder srm 310 div1

    problem1 link 先计算出最上面.最下面一层,根据最上面一层的数量计算答案. import java.util.*; import java.math.*; import static ja ...

  7. ssm项目中 数据库和资源的备份

    备份 备份很重要 数据库的备份 mysqldump -u用户名 -p密码 所需要备份的数据库 > ~/backup/sql/o2o`date +%Y%m%d%H%M%S`.sql 资源的备份 t ...

  8. Summary on Visual Tracking: Paper List, Benchmarks and Top Groups

    Summary on Visual Tracking: Paper List, Benchmarks and Top Groups 2018-07-26 10:32:15 This blog is c ...

  9. 4-Three-Matterhorn man

    What was the main objective of early mountain climbers?   ①Modern alpinists try to climb mountains b ...

  10. 【sql server】索引详解

    索引可以理解为一种特殊的目录结构. sql server提供两种索引形式: 聚集索引和非聚集索引. 怎么理解这两种形式. 拿我们常用的字典举例来说, 一个字典好比数据库中的一个表.那么当我们想从字典中 ...