hp raid配置
http://www.cnblogs.com/zhangxinglong/p/5585139.html
[root@192e168e100e27 ~]# fdisk -l Disk /dev/nvme0n1: 1601.2 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/nvme1n1: 1601.2 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdm: 480.1 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes
Disk label type: dos
Disk identifier: 0x00017fe7 Device Boot Start End Blocks Id System
/dev/sdm1 * Linux
/dev/sdm2 c W95 FAT32 (LBA)
Partition does not start on physical sector boundary. Disk /dev/sda: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdb: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdf: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdc: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdg: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdd: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sde: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdj: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdl: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdk: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdh: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes Disk /dev/sdi: 4000.8 GB, bytes, sectors
Units = sectors of * = bytes
Sector size (logical/physical): bytes / bytes
I/O size (minimum/optimal): bytes / bytes
查看raid卡信息
[root@192e168e100e27 yum.repos.d]# hpssacli ctrl all show status Smart HBA H240 in Slot (RAID Mode)
Controller Status: OK 查看raid状态
[root@192e168e100e27 yum.repos.d]# hpssacli ctrl slot= ld all show Smart HBA H240 in Slot array A logicaldrive (447.1 GB, RAID , OK) 查看物理硬盘状态
[root@192e168e100e27 yum.repos.d]# hpssacli ctrl slot= pd all show status physicaldrive 1I:: (port 1I:box :bay , 480.1 GB): OK
physicaldrive 1I:: (port 1I:box :bay , 480.1 GB): OK 查看物理硬盘
[root@192e168e100e27 yum.repos.d]# hpssacli ctrl slot= pd all show Smart HBA H240 in Slot array A physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK)
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK) 查看裸机磁盘信息
[root@192e168e100e27 ~]# hpssacli ctrl slot= logicaldrive show Smart HBA H240 in Slot array A Logical Drive:
Size: 447.1 GB
Fault Tolerance:
Heads:
Sectors Per Track:
Cylinders:
Strip Size: KB
Full Stripe Size: KB
Status: OK
MultiDomain Status: OK
Caching: Disabled
Unique Identifier: 600508B1001C4E74DC449B2B39F2C592
Disk Name: /dev/sdm Mount Points: / 447.0 GB Partition Number
OS Status: LOCKED
Logical Drive Label: 00307D90PDNNK0BRH970WR8DA0
Mirror Group :
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK)
Mirror Group :
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK)
Drive Type: Data
LD Acceleration Method: HP SSD Smart Pat [root@192e168e100e27 ~]# hpssacli ctrl slot= physicaldrive 1I:: show Smart HBA H240 in Slot array A physicaldrive 1I::
Port: 1I
Box:
Bay:
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 480.1 GB
Native Block Size:
Firmware Revision: 4IYVHPG1
Serial Number: PHYS738102JD480BGN
Model: ATA VK000480GWJPE
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C):
Maximum Temperature (C):
Usage remaining: 99.98%
Power On Hours:
Estimated Life Remaining based on workload to date: days
SSD Smart Trip Wearout: False
PHY Count:
PHY Transfer Rate: .0Gbps
Drive Authentication Status: OK
Carrier Application Version:
Carrier Bootloader Version:
列出RAID卡控制器的信息
[root@192e168e100e62 ~]# hpssacli
HP Smart Storage Administrator CLI 2.0.22.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console. => ctrl all show detail config Smart HBA H240 in Slot (RAID Mode)
Bus Interface: PCI
Slot:
Serial Number: PDNNK0BRH970NI
Cache Serial Number: PDNNK0BRH970NI
RAID (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 5.52
Rebuild Priority: High
Surface Scan Delay: secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: secs
Cache Board Present: False
Drive Write Cache: Disabled
Total Cache Size: MB
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C):
Number of Ports: Internal only
Encryption: Disabled
Encryption Login Status: Not Logged In
Encryption Allow Plaintext Volumes: Disallow
Encryption Key Management Mode: Not Set
Encryption Supported: True
Encryption RTC SRAM Status: Passed
Encryption Master Key reset in Progress: False
Encryption Local Key Cache Enabled: False
Encryption Crypto Officer Password: Not Set
Encryption User Password: Not Set
Encryption License Installed: True
Encryption FW Locked for Update: Unlocked
Encryption Controller Password: Not Set
Encryption Local Key Cache Supported: True
Encryption Controller Locked: Unlocked
Encryption Has Suspended Controller Password: False
Encryption Controller Password Unlock Attempts Remaining:
Encryption Logical Drive(s) Locked For Missing Controller Password: False
Encryption Password Recovery Parameters Set: False
Encryption Master Key: Not Set
Encryption Remote Mode Master Key Mismatch: False
Encryption/HP SSD Smart Path Mixing Supported: True
Encryption/HP SmartCache Mixing Supported: False
Driver Name: hpsa
Driver Version: 3.4.
Driver Supports HP SSD Smart Path: True
Negotiated PCIe Data Rate: PCIe 3.0 x8 ( MB/s)
Controller Mode: RAID Mode
Controller Mode Reboot: Not Required
Latency Scheduler Setting: Disabled
Current Power Mode: MaxPerformance Internal Drive Cage at Port 1I, Box , OK
Power Supply Status: Not Redundant
Serial Number:
Drive Bays:
Port: 1I
Box:
Location: Internal Physical Drives
Smart HBA H240 in Slot
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK)
Smart HBA H240 in Slot
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK) Array: A
Interface Type: Solid State SATA
Unused Space: MB
Status: OK
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: enable Logical Drive:
Size: 447.1 GB
Fault Tolerance:
Heads:
Sectors Per Track:
Cylinders:
Strip Size: KB
Full Stripe Size: KB
Status: OK
MultiDomain Status: OK
Caching: Disabled
Unique Identifier: 600508B1001C2D64A75B6E41A3467347
Disk Name: /dev/sdm Mount Points: / 447.0 GB Partition Number
OS Status: LOCKED
Logical Drive Label: 003083A1PDNNK0BRH970NI35AF
Mirror Group :
Smart HBA H240 in Slot
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK)
Mirror Group :
Smart HBA H240 in Slot
physicaldrive 1I:: (port 1I:box :bay , Solid State SATA, 480.1 GB, OK)
Drive Type: Data
LD Acceleration Method: HP SSD Smart Path physicaldrive 1I::
Port: 1I
Box:
Bay:
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 480.1 GB
Native Block Size:
Firmware Revision: 4IYVHPG1
Serial Number: PHYS738102HC480BGN
Model: ATA VK000480GWJPE
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C):
Maximum Temperature (C):
Usage remaining: 99.98%
Power On Hours:
Estimated Life Remaining based on workload to date: days
SSD Smart Trip Wearout: False
PHY Count:
PHY Transfer Rate: .0Gbps
Drive Authentication Status: OK
Carrier Application Version:
Carrier Bootloader Version: physicaldrive 1I::
Port: 1I
Box:
Bay:
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 480.1 GB
Native Block Size:
Firmware Revision: 4IYVHPG1
Serial Number: PHYS738200FN480BGN
Model: ATA VK000480GWJPE
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C):
Maximum Temperature (C):
Usage remaining: 99.98%
Power On Hours:
Estimated Life Remaining based on workload to date: days
SSD Smart Trip Wearout: False
PHY Count:
PHY Transfer Rate: .0Gbps
Drive Authentication Status: OK
Carrier Application Version:
Carrier Bootloader Version: 6
hp raid配置的更多相关文章
- hp raid json
hp机器均已在装OS之前划好raid,统一规格为2*480G SSD, 12*4T SATA ,2*1.6T SSD,其中2*480G SSD做系统盘,划分raid1 已知disk controlle ...
- 服务器RAID配置全程与RAID基础知识
服务器RAID配置全程 一.RAID介绍 RAID是Redundent Array of Inexpensive Disks的缩写,直译为“廉价冗余磁盘阵列”,也简称为“磁盘阵列”.后来RAID中的字 ...
- CentOS6软raid配置与管理
事先添加硬盘设备sdb.sdc.sdd.sde.无论是物理硬盘还是虚拟硬盘,最好使用同型号同大小的硬盘. 创建raid设备 支持raid0.1.4.5.6级别 # mdadm -C /dev/md0 ...
- (转)Ctrl+H 浪潮Raid配置文档
说明 本手册适用于LSI芯片Raid卡 包括但不限于Inspur 2008/2108 Raid卡.LSI 9240/9260/9261/9271 等Raid卡. 不同型号的Raid卡在某些功能上的支持 ...
- Ctrl+H 浪潮Raid配置文档
说明 本手册适用于LSI芯片Raid卡 包括但不限于Inspur 2008/2108 Raid卡.LSI 9240/9260/9261/9271 等Raid卡. 不同型号的Raid卡在某些功能上的支持 ...
- LSI SAS3008 RAID配置方法
7.1 概述 LSI SAS3008 RAID 控制卡(以下简称LSI SAS3008)是基于Fusion-MPT™ (消息传递技术)架构的8端口12Gbit/s SAS控制器,并采用PCIe3.0 ...
- 浪潮服务器NF84260M3安装Windows server 2012 R2 RAID配置
这里是已经做了RAID6,再做系统 浪潮服务器NF84260M3 U盘启动,光盘刻录 Windows server 2012 R2 镜像,地址:迅雷下载,ed2k://|file|cn_windows ...
- 服务器硬件和RAID配置
服务器 硬件和RAID配置 目录 一.RAID 磁盘阵列介绍 1.1.RAID 0(条带化存储) 1.2.RAID 1(镜像存储) 1.3.RAID 5 1.4.RAID 6 1.5.RAID 1+0 ...
- 服务器硬件及RAID配置实践
服务器硬件及RAID配置实践 1.RAID磁盘阵列介绍 2.创建RAID磁盘阵列 1.RAID:中文简称为独立冗余磁盘阵列 把多块独立的物理硬盘按不同的方式组合起来形成一个硬盘组(逻辑硬盘),从而提供 ...
随机推荐
- Poj(2560),最小生成树,Prim
题目链接:http://poj.org/problem?id=2560 只想说“全都是套路”,关键建图. #include <stdio.h> #include <string.h& ...
- bpclntcmd一条神奇的命令,解决新安装nbu客户端无法连接的问题 (屡试不爽神命令)
1. bpclntcmd案例 bpclntcmd -clear_host_cache bpclntcmd – 测试 NetBackup 系统的功能,并在 NetBackup 客户端上启用光纤传输服务 ...
- Mac下安装OpenCV3.0和Anaconda和环境变量设置
入手Mac几天了,想在Mac OS下玩玩OpenCV和keras,间歇捣鼓了两天,终于搞定zsh.OpenCV3.0以及Anaconda.OpenCV3.0刚发布不久,这方面的资料也不是很多,能够查到 ...
- mysql默认字符集问题
最近在使用mysql的时候出现了奇怪的乱码问题,最开始发现mysql的字符集的确存在一些问题. 经过修改配置文件/etc/my.cnf [mysqld] character-set-server=ut ...
- 第49章 在SRAM中调试代码—零死角玩转STM32-F429系列
第49章 在SRAM中调试代码 全套200集视频教程和1000页PDF教程请到秉火论坛下载:www.firebbs.cn 野火视频教程优酷观看网址:http://i.youku.com/fir ...
- C# 使用布尔操作符
布尔操作符(Boolean operator)是求值结果要么为true,要么为false的一种操作符.C#提供了几个非常有用的布尔操作符,其中最简单的是NOT(求反)操作符,它使用感叹号(!)来表示. ...
- windows安装配置mongodb及图形工具MongoVUE
解压安装包到D:\Program Files\mongodb 建立数据库目录 D:\Program Files\mongodb\data 建立日志目录 D:\Program Files\mongodb ...
- eclipse环境Dynamic web module version 3.1版本的进步,简化Dynamic web object 中Servlet类的配置,不用web.xml配置<Servlet>
eclipse环境Dynamic web module version 3.1版本之前,Dynamic web object 中Servlet类的配置,要在web.xml 配置<Servlet& ...
- 关于ACL中通配符掩码(反掩码)认识
ACL(Access Control List) 访问控制列表在作为数据包的过滤器以及在对指定的某种类型的数据包的优先级,起到了对某些数据包的优先级起到了限制流量的作用,减少了网络的拥塞. ...
- vue 用户输入搜索 与无限下拉
vue项目中,用户输入关键字搜索,并且手机端做无限下拉 watch: { 'getListForm.searchKey'(val) { this.radioChange(); // 还有其他逻辑,内部 ...