Article ID: 939308 - View products that this article applies to.

Expand all | Collapse all

Symptoms

You perform a system recovery in Microsoft Windows SharePoint Services 3.0 in which the configuration database is restored. Then, you try to modify or to delete an alternate access mapping.
When you do this, you receive an error message that resembles the following error message:

An update conflict has occurred, and you must re-try this action. The object SPAlternateUrlCollection Name=WEBAPPLICATION Parent=SPFarm Name=SharePoint_Config is being updated by DomainName\UserName1, in the w3wp process, on machine ServerName. View the tracing log for more information about the conflict.

When you view the Unified Logging Service (ULS) log files, you see an entry that resembles the following entry:

Date Time w3wp.exe (0x1620) 0x1988 Windows SharePoint Services Topology 8xqz Medium Updating SPPersistedObject SPAlternateUrlCollection Name=WEBAPPLICATION Parent=SPFarm Name=SharePoint_Config. Version: 16449 Ensure: 0, HashCode: 30474330, Id: 609b3309-241a-4193-8289-1bba6a70be50, Stack: at Microsoft.SharePoint.Administration.SPPersistedObject.Update() at Microsoft.SharePoint.Administration.SPAlternateUrlCollection.Update() at Microsoft.SharePoint.ApplicationPages.IncomingUrlPage.BtnSave_Click(Object sender, EventArgs e) at System.Web.UI.WebControls.Button.OnClick(EventArgs e) at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) at System.Web.UI.WebControls.Button.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) at System.Web.UI.Page.ProcessRequest(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) at System.Web.UI.Page.ProcessRequest() at System.Web.UI.Page.ProcessRequestWithNoAssert(HttpContext context) at System.Web.UI.Page.ProcessRequest(HttpContext context) at ASP._admin_editincomingurl_aspx.ProcessRequest(HttpContext context) at System.Web.HttpApplication.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() at System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) at System.Web.HttpApplication.ResumeSteps(Exception error) at System.Web.HttpApplication.System.Web.IHttpAsyncHandler.BeginProcessRequest(HttpContext context, AsyncCallback cb, Object extraData) at System.Web.HttpRuntime.ProcessRequestInternal(HttpWorkerRequest wr) at System.Web.HttpRuntime.ProcessRequestNoDemand(HttpWorkerRequest wr) at System.Web.Hosting.ISAPIRuntime.ProcessRequest(IntPtr ecb, Int32 iWRType) 06/06/2007 14:36:31.51 w3wp.exe (0x1620) 0x1988 Windows SharePoint Services Topology 75bd High UpdatedConcurrencyException: The object SPAlternateUrlCollection Name=WEBAPPLICATION Parent=SPFarm Name=SharePoint_Config was updated by another user. Determine if these changes will conflict, resolve any differences, and reapply the second change. This error may also indicate a programming error caused by obtaining two copies of the same object in a single thread. Previous update information: User: DomainName\UserName1 Process:w3wp Machine:ServerName Time:Date Time Current update information: User: DomainName\UserName2 Process:w3wp Machine:ServerNameDate Time w3wp.exe (0x1620) 0x1988 Windows SharePoint Services Topology 8xqy High ConcurrencyException: Old Version : 16449 New Version : 0

Back to the top | Give Feedback

Cause

This issue occurs if the contents of the file system cache on the front-end servers are newer than the contents of the configuration database. After you perform a system recovery, you may have to manually clear the file system cache on the local server.

Back to the top | Give Feedback

Resolution

To resolve this issue, clear the file system cache on all servers in the server farm on which the Windows SharePoint Services Timer service is running. To do this, follow these steps:

  1. Stop the Timer service. To do this, follow these steps:
    1. Click Start, point to Administrative Tools, and then click Services.
    2. Right-click Windows SharePoint Services Timer, and then click Stop.
    3. Close the Services console.
  2. On the computer that is running Microsoft Office SharePoint Server 2007 and on which the Central Administration site is hosted, click Start, click Run, type explorer, and then press ENTER.
  3. In Windows Explorer, locate and then double-click the following folder:

    Drive:\Documents and Settings\All Users\Application Data\Microsoft\SharePoint\Config\GUID

    Notes

    • The Drive placeholder specifies the letter of the drive on which Windows is installed. By default, Windows is installed on drive C.
    • The GUID placeholder specifies the GUID folder.
    • The Application Data folder may be hidden. To view the hidden folder, follow these steps:
      1. On the Tools menu, click Folder Options.
      2. Click the View tab.
      3. In the Advanced settings list, click Show hidden files and folders under Hidden files and folders, and then click OK.
    • In Windows Server 2008, the configuration cache is in the following location:

      Drive:\ProgramData\Microsoft\SharePoint\Config\GUID

  4. Back up the Cache.ini file.
  5. Delete all the XML configuration files in the GUID folder. Do this so that you can verify that the GUID folder is replaced by new XML configuration files when the cache is rebuilt.
    Note When you empty the configuration cache in the GUID folder, make sure that you do not delete the GUID folder and the Cache.ini file that is located in the GUID folder.
  6. Double-click the Cache.ini file.
  7. On the Edit menu, click Select All.
  8. On the Edit menu, click Delete.
  9. Type 1, and then click Save on the File menu.
  10. On the File menu, click Exit.
  11. Start the Timer service. To do this, follow these steps:
    1. Click Start, point to Administrative Tools, and then click Services.
    2. Right-click Windows SharePoint Services Timer, and then click Start.
    3. Close the Services console.

    Note The file system cache is re-created after you perform this procedure. Make sure that you perform this procedure on all servers in the server farm.

  12. Make sure that the Cache.ini file has been updated. For example it should no longer be 1 if the cache has been updated.
  13. Click Start, point to Programs, point to Administrative Tools, and then click SharePoint 3.0 Central Administration.
  14. Click the Operations tab, and then click Timer job status under Global Configuration.
  15. In the list of timer jobs, verify that the status of the Config Refresh entry is Succeeded.
  16. On the File menu, click Close.

Back to the top | Give Feedback

Properties

Article ID: 939308 - Last Review: February 4, 2013 - Revision: 5.0

Applies to
  • Microsoft Windows SharePoint Services 3.0
  • Microsoft Office SharePoint Server 2007
  • Microsoft SharePoint Foundation 2010
  • Microsoft SharePoint Server 2010
  • Microsoft SharePoint Foundation 2013
  • Microsoft SharePoint Server 2013

Error message when you try to modify or to delete an alternate access mapping in Windows SharePoint Services 3.0: "An update conflict has occurred, and you must re-try this action"的更多相关文章

  1. Parser Error Message: Access is denied【转】

    PRB: Access Denied Error When You Make Code Modifications with Index Services Running View products ...

  2. Compiler Error Message: CS0016: Could not write to output

    打开网页是报错: Server Error in '/' Application. Compilation Error Description: An error occurred during th ...

  3. Compiler Error Message: CS0016: Could not write to output file 回绝访问

    Compiler Error Message: CS0016: Could not write to output file 'c:\Windows...dll' 拒绝访问 C:\Windows\Te ...

  4. Oracle Error - "OCIEnvCreate failed with return code -1 but error message text was not available".

    ISSUE: When trying to connect to an Oracle database you receive the following error: "OCIEnvCre ...

  5. 网站部署后Parser Error Message: Could not load type 的解决方案

    asp.net 的Webproject 项目是在64bit机上开发,默认选项发布后,部署到32bit的服务器上,出现Parser Error Message: Could not load type的 ...

  6. [BTS] The adapter "SQL" raised an error message. Details "The Messaging Engine is shutting down. ".

    Get a warning in event log. Log Name:      ApplicationSource:        BizTalk ServerDate:          3/ ...

  7. Fix the “No Private Key” Error Message

    This article will show you how to correct the “No Private Key” error message in Windows Internet Inf ...

  8. undefined reference to typeinfo - C++ error message

    undefined reference to typeinfo - C++ error message There are some compiler and loader error message ...

  9. "This connection is untrusted" - Firefox error message

    Error Messages I am receiving the following error message in Firefox: After selecting Cancel to clos ...

随机推荐

  1. (转)在低版本的SDK里使用高版本函数@SuppressLint("NewApi") or @TargetApi?

    @SuppressLint 和 @TargetApi达到的效果是一样的,相对于SuppressLint ,TargetApi会根据函数里使用的API,严格匹配SDK版本,给出编译错误,但是Suppre ...

  2. Code the Tree(图论,树)

    ZOJ Problem Set - 1097 Code the Tree Time Limit: 2 Seconds      Memory Limit: 65536 KB A tree (i.e. ...

  3. vmware workstation11+centos7+lnmp一键安装包 环境搭建

    vmware workstation11 1.下载:http://pan.baidu.com/s/1gecipOJ 2.安装:直接下一步. centos7 1.下载:网易镜像 http://mirro ...

  4. 标志数在wordcount程序中的应用与拓展

    wordcount程序要求测出文本中的单词数,字符数和行数. 设计思路: 将文件读入,逐字检测,检测到空格单词数加一,检测到回车行数单词数加一,如果既不是回车也不是空格则说明是字符,字符数加一 编程时 ...

  5. 浅析I/O模型及其设计模式

    前言 I/O在软件开发中的重要性无需多言,无论是在操作系统.网络协议.DBMS这种底层支撑软件还是在移动APP,大型网站服务器等应用软件的开发中都是最核心最重要的部分.特别是现在软件服务使用量和数据量 ...

  6. LeetCode-95. Unique Binary Search Trees II

    Description: Given n, generate all structurally unique BST's (binary search trees) that store values ...

  7. vertical-align两种应用场合

    vertical-align两种应用场合 (1)用在td/th中或display:table-cell元素中:让当前元素中的文本内容在竖直方向上居中    css部分:    .content{   ...

  8. 【Spark】----Spark on Yarn

    最近从Hadoop 1.x 转到Hadoop 2.x 同时将一些java 程序转为Scala的程序将平台上的代码减少了很多,在实施的过程中,开到一些Spark相关的YARN的部署上都是基于之前的Had ...

  9. Winform开发框架主界面设计展示

    做了好多年Winform的程序的开发,主窗口的界面设计一般都要求做的更好一些,可以根据不同的系统功能模块进行归类整合,能使客户迅速寻找到相关功能的同时,也能感觉到整体性的美观大方,因此主窗口的界面设计 ...

  10. istView的项移除

    如标题所言,是做删除ListView绑定项的功能的:鉴于这个功能当时确实花费了很多时间,并且网上也找不到删除所需的案例,所以,我就做了一份案例,仅供各位前辈和同行进行参考,如有不当之处,还望指点,我将 ...